Sievers InnovOx On-Line TOC Analyzer

Real-time continuous monitoring for process control and regulatory compliance

Sievers InnovOx On-Line Total Organic Carbon (TOC) Analyzers offer continuous organics monitoring and multi-stream capabilities. The multi-stream capability allows user to run up to five samples if processes do not require continuous monitoring. The Sievers InnovOx On-Line has a dynamic operating range of 50 ppb to 50,000 ppm. Its patented Supercritical Water Oxidation technique allows for superior TOC recovery, accuracy, and instrument robustness. 

Download Brochure Here

Learn more about real-time monitoring with Sievers InnovOx On-Line

The analyzers are compliant with US EPA Method 415.1, US EPA Method 415.3, US EPA Method 9060A, CEN Method DIN EN 1484, ISO 8245, and ASTM D5173.

Features and Benefits

InnovOx On-Line Features and Benefits

Wide dynamic range up to 50,000 ppm TOC

  • Patented supercritical water oxidation (SCWO) for superior TOC recovery and high reliability
  • Run up to five sample streams
  • Reliable NDIR detection technology with no moving parts
  • Straightforward operation
  • Versatile measurement modes include TOC (TC-IC) or NPOC
  • COD/BOD reporting
  • Handles tough TOC samples, like cellulose and brine

Applications

  • Biological wastewater plant optimization
  • Wastewater monitoring
  • High salt and brine monitoring
  • Industrial monitoring

Specifications

InnovOx On-Line Specifications

Operating Specifications*

Analysis Modes NPOC, TOC, (TC-IC), TC, IC
Range 0.05 to 50,000 ppm TOC
Precision RSD ≤3% of reading at >5 ppm NPOC or TOC
Accuracy Greater of ±3% or ±.25 ppm, 1 to 100 ppm, NPOC or TOC
Linearity R2 ≥ 0.995, measured as NPOC
LOD <50ppb
TOC Calibration Stability Up to 6 months
Analysis Time 2.6 to 8.3 minutes
Particle Diameters in Sample ≤800 µm diameter
Sample Temperature 10-60 °C (41-140 °F)
Ambient Temperature Range 10 to 40 °C (50-104 °F)
Sampling Ambient pressure, 0.08 to 2.82 mL sample volume per analysis

Analyzer Specifications

Sample Capacity Up to 120 with optional Autosampler** (or single standard vial port)
Outputs Ethernet Port (1); USB Ports (3)
Display Color LCD w/touch-screen
Power 100 – 240 ± 10% VAC, 50 – 60 Hz, 400 VA
Installation/Overvoltage Category II
Dimensions H: 52.05 cm (20.5 in.); W: 32.26 cm (12.7 in.); D:58.42 cm (23.0 in)
Dimensions (Autosampler) H: 52.2 cm (20.5 in.); W: 31.1 cm (12.25 in.); D: 53.3 cm (21.0 in.)
Weight 22.41 kg (49.4 lb); 14.1 kg (31.1 lb) for optional Autosampler
Safety Certifications CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 NO. 61010-1

Environment

Maximum Relative Humidity Up to 95%, non-condensing
Normal Operating Indoor use only. Keep instrument and reagents out of direct sunlight.
Maximum Altitude 3,000 m (9,800 ft)
Pollution Degree 2

* Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.

** Up to 63 sample tubes for 40mL and 60mL vials. Up to 120 sample tubes for 35mL vials.

*** NPOC mode, bottled N2 as carrier gas. This performance is achieved under controlled conditions where variables that influence low-level performance have been minimized or eliminated. This performance may not be achievable on instruments delivered before August 2016.

Accessories

InnovOx Lab Options and Accessories

  • High-temperature sampler: allow for monitoring of samples up to 85ºC. Ideal for use in steam condensate and cooling tower applications  

  • Wastewater sampler: configurable for either low to moderate or high levels of particle content without the maintenance of filtering systems 

  • Fail safe: monitors for the presence of sample flow and adequate supply of reagents/check standards to increase reliability 

  • Exterior pumps: for applications where a pressurized sample is not available