Veolia Water Technologies & Solutions

Sievers M5310 C Portable TOC Analyzer

Portable, lightweight analyzer designed to meet regulations and optimize processes

The Sievers M5310 C Portable Total Organic Carbon (TOC) Analyzer is the most versatile of the M5310 C series. Its light weight and compact design makes it a powerful troubleshooting analysis tool that can be used for single grab samples, in autosampler mode, or in a process stream for continuous on-line TOC measurement. Offering an operating range of 4 ppb to 50 ppm, this analyzer is engineered to support regulatory compliance and processes optimization goals. 

Learn more about the extreme versatility of the Sievers M5310 C Portable

Sievers M5310 C Portable features two operating modes - continuous or grab sample. Equipped with the Integrated On-Line Sampling System (IOS System™), the M5310 C Portable allows the easy introduction of external standards and samples without removing the instrument from the continuous sample source. 

Features and Benefits

M5310 C Portable Features and Benefits

  • Provides readings in only two minutes
  • Simple and intuitive
  • Automated calibration, verification, and data analysis enable unattended operation
  • Automatically calculates percent TOC removal for influent and effluent streams or samples
  • The Autoreagent feature automatically establishes optimal flow rates for each sample
  • Pre-calibrated for simple installation
  • Minimal maintenance — typically just a few hours per year 
  • Self-contained with small footprint and internal reagent packs — no external chemicals, catalysts, or gas supplies required.
  • Easy data communications — export or collect data via USB, 4-20 mA, or Modbus TCP/IP outputs
  • IOS system allows testing of external samples and standards without removing the analyzer from the continuous water source
  • The grab-mode, alphanumeric labeling feature allows individual labeling of each grab sample for easy recall later on
     

Specifications

M5310 C Portable Specifications

Operating Specifications*

Range 4 ppb to 50 ppm
Precision < 1% RSD
Accuracy ± 2% or ± 0.5 ppb, whichever is greater
Display Readout 3 significant digits
Sample Type On-line continuous, Autosampler, or discrete grab sample, timed on-line, TOC removal on-line, TOC removal grab
Calibration Typically stable for 12 months
Analysis Time 2 minutes
Sample Temperature** 5–95 °C (41–203 °F)
Ambient Temperature 5–40 °C (41–104 °F)
Sample Pressure 100 psig
Required Sample Line Flow Rate >50 mL/min (for on-line mode)
Instrument Sample 
Flow Rate
0.5 mL/min

Analyzer Specifications

On-Line Inlet(s) One stream
Outputs 4-20 mA output (3); alarm outputs (4); binary input (1); USB device port (1); USB host ports (2); Ethernet
Display  7" WVGA, Color LCD with touch-screen
Power 100 – 240 V~, 50 - 60 Hz, 100 VA
Fuses Replace with same type and size fuse: T 1.6 A 250 VAC Fuse (Slow Blow), size 5 X 20 mm appliance inlet
Dimensions H: 39.5 cm (15.4 in); W: 22.9 cm (9.0 in); D: 46.4 cm (18.3 in)
Weight 9.8 kg (21.6 lb)
Safety Certifications ETL, CE see Declaration of Conformity 
Enclosure Rating IP-21

Environment

Maximum Relative Humidity 0 - 95%, non-condensing
Maximum Altitude 3,000 m (9.800 ft)
Pollution Degree 2

The UV lamp inside this product contains mercury and must be recycled or disposed of in accordance with local, state, and federal laws.

*Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.
**Sample temperature above 60 °C requires optional PVDF iOS.

Accessories

M5310 C Options and Accessories

  • Sievers Autosampler: enables 24+ hours of unattended sample analysis (63 or 120 sample position capacity)

  • DataPro2 Software: integrates the Autosampler with the M5310 C Lab, providing timesaving features to maximize productivity and ensure easy TOC data management.

  • Autosampler rinse station: flushes the sample inlet system and needle with a flowing water source, maximizing analytical performance of samples of varying concentrations.

  • Pre-filter kits: provide sample conditioning to ensure optimal instrument performance. Three application-specific kits are available: normal use, heavy use, and treated drinking water

Sievers Autosampler